Remote indicator II. Part no. 11506

The remote indicator II allows the safe remote monitoring of the oil mist concentration from outside the engine room e.g. from the engine control room.
In use with a VN93 or VN87plus, it is possible to monitor the relative opacity and the state of one OMD device similar to the OMD display. The connection to the VN/93 and VN/87plus units is realized by a RS485 two-wire bus.

Optional the remote indicator II can be connected to a VN87-EMC unit. This connection to theVN/87-EMC is realized as a two-wire analog interface. If a VN/87-EMC is connected to the remote indicator II, the device monitors only the oil mist concentration and not the state of the OMD device.

Benefits:

  • Full overview of “real time” measurement of oil mist concentration
  • Secures personnel’s situation in cases of high oil mist alarm
  • Meet’s the IACS UR 10.11 requirement
  • Easy to install

Accessories:

Remote indicator unit II Part no. 11506
Connector FK-MCP 1,5/12-STF-3,81* Part no. 11507
Grommet Part no. 11501
Network terminator Part no. 11502
Front glass plate for horizontal installation Part no. 11510
Front glass plate for vertical  installation Part no. 11511
Jumper Part no. 11512
5 x label engine type Part no. 11508

Connection diagram for remote indicator II to VN/93 & VN/87plus:

Name: Pin- no. Remote indicator II: Connected to pin- no. on oil mist detector:
RS485 A 1 Pin 13 of VN/93 and VN/87plus
RS485 B 2 Pin 11 of VN/93 and VN/87plus
RS485 GND 3 ---
Optional current interface + 4 ---
Optional current interface - 5 ---
VN/87- PWM interface + 6 ---
VN/87- PWM interface - 7 ---
4- 20 mA Output + (max. 220 ohm) 8 Optional to alarm monitoring system
4- 20mA  Output - 9 Optional to alarm monitoring system
Earth 10 Earth & data cable shield
Power supply GND 11 0  Volts
Power supply 24 Volts 12 +24 Volts DC



Connection diagram for remote indicator II to VN/87EMC:

Name: Pin- no. Remote indicator II: Connected to pin- no. on oil mist detector:
RS485 A 1 ---
RS485 B 2 ---
RS485 GND 3 ---
Optional current interface + 4 ---
Optional current interface - 5 ---
VN/87- PWM interface + 6 Pin 9 of VN/87 EMC
VN/87- PWM interface - 7 PIN 10 of VN/87 EMC
4- 20 mA Output + (max. 220 ohm) 8 Optional to alarm monitoring system
4- 20mA Output - 9 Optional to alarm monitoring system
Earth 10 Earth & data cable shield
Power supply GND 11 0 Volts
Power supply 24 Volts 12 +24 Volts DC

.
Webdesign & Publiseringsløsning levert av Argo Internett AS ©